EN

best wood FIBRE air injected insulation Optimal and joint-free

FIBRE offers the possibility to insulate even complicated compartments. A joint-free insulation can be guaranteed. Thanks to the interconnection of the wood fiber, a constant resistance against settling can be obtained at a fill density of 38 - 45 kg/m³. FIBRE air injected wood fiber insulation can be used in industrial prefabrication as well as for renovation works.

best wood FIBRE
  • 0.038 [W/mK]

    Nominal value of thermal conductivity λD according to ETA 16/0954

  • 0.038 [W/mK]

    Declared thermal conductivity λD according to SIA 279 (Switzerland)

  • 0.040 [W/mK]

    Rated value of thermal conductivity λB according to ETA 16/0954

  • 38 - 45 [kg/m³]

    Density

Fields of application

  • Insulation between rafters
  • Infilling insulation of walls in wooden framework and timber frame constructions
  • Insulation of wooden ceilings
  • Insulation of upper floor slabs
  • Insulation of ribbing on mineral substrates

Fields of application according to DIN 4108-10
DZ, DI-zk, WH, WI-zk, WTR

Delivery formats

Bale size 800 x 420 x 320 mm
Pallet size 0,85 x 1,20 x 2,50 m (Euro pallet)
Packaging Stretch cover

Technical data

Type approvalETA 16/0954
Recommended blow-in density, closed cavities38 - 45 [kg/m³]
Nominal value of thermal conductivity λD0.039 [W/mK]
Rated value of thermal conductivity λB0.041 [W/mK]
Recommended blow-in density, open blown*approx. 28 [kg/m³]
Nominal value of thermal conductivity λD0.039 [W/mK]
Rated value of thermal conductivity λB0.040 [W/mK]
Reaction to fire according to DIN EN 13501-1E
Construction material class according to DIN 4102-1B2
Linear flow resistance> 5 [kPa·s/m²]
Full declarationWood fibers, fire retardants ammonium sulphate (natureplus-compliant)
Water vapor diffusion resistance μ 2
Specific heat capacity 2100 [J/(kgK)]
Waste code according to AVV 030105, 170201
* An installation thickness that has been reduced by 20 % must be used when calculating the thermal resistance of components with open blowing.

Quality

For your and our safety, we take great care to ensure a high standard of quality.

Briefly explained: best wood FIBRE air injected insulation

Accessories

Here you will find popular accessories for this product.

best wood keyhole saw LH for air injected insulation in board materials

Keyhole saw LH for air injected wood fiber insulation in board materials

Powerful keyhole saw for the professional production of injection openings in board materials.

best wood keyhole saw (ED) with ejector for air injected wood fiber insulation

best wood keyhole saw (ED) with ejector for air injected wood fiber insulation

The drill core is used for closing after the injection opening.

best wood cork plug

best wood cork plug

Tapered sealing cork for simple and time-saving closure of injection openings in hard panelling materials such as OSB boards or fiber-reinforced plasterboard.

Suitable accessories

Here you will find everything that is right and good for working and processing our insulation products.

Reference Three-storey with best wood SCHNEIDER A reference project for plaster baseboard and wood fibre insulation

In Bettenweiler, a three-storey multi-family house was built using the timber frame construction method - naturally with best wood SCHNEIDER

  • Location 88263 Bettenweiler, Germany
  • Building type Residential buildings
  • Building measure New buildings

Reference Price-suspicious plus-energy house A single-family show house sets standards

In Altshausen, a single-family house with energy standard KfW 40 Plus has been nominated for the German Model House Award - we're keeping our fingers crossed!

  • Location 88361 Altshausen, Germany
  • Building type Residential buildings
  • Building measure New buildings

Reference Production hall with KfW Efficiency House 40 energy standard Timeless workspaces made of timber ...for timber!

When timber constructors build timber halls for timber buildings: A modern, light-flooded and optimally insulated new working environment for the employees of the Braumandl carpentry workshop.

  • Location 91608 Geslau, Germany
  • Building type Industrial and commercial buildings, Operational buildings
  • Building measure New buildings

Reference Compact on the one hand and spacious on the other This well-designed apartment building in a rural setting makes it possible to effectively use the given space

In Rupertshofen (Southern Germany), nine residential units and one commercial unit were built to the German KfW 40 Plus efficiency standard. Both CLT BOX - ROOF and CLT BOX Ceiling systems were used - and of course wood fibre insulation materials from best wood SCHNEIDER.

  • Location 88448 Attenweiler, Germany
  • Building type Residential buildings
  • Building measure New buildings

Reference Office building with insulated best wood CLT BOX as a flat roof Sustainable timber construction in a modern and functional design

The clients attached great importance to natural and sustainable building materials when constructing this detached extension. One highlight: the flat roof, for which our best wood CLT BOX elements in visible quality were used.

  • Location 88085 Langenargen, Campus Krumme Jauchert, Germany
  • Building type Office and administration buildings
  • Building measure New buildings, Extension
Loading